Voltage Data Logger
Record inputs from any 0-20 mA or 0-5V transmitter for pH, flow, fluid level,
or any variable you choose. This flexible data logger allows you to
create your own recording instrument
- 5-year battery life
- 32,512 data point storage
- User selectable 0-20mA or 0-5V
|
Accuracy - Recorder Only
|
±0.1
|
|
Ambient Operating RH Conditions
|
0-95% RH (non-condensing)
|
|
Ambient Operating Temperature Conditions
|
-40 to 176F (-40 to 80C)
|
|
Approvals
|
CE
|
|
Battery Life (Avg)
|
5 years
|
|
Channels
|
2 (1 current/1 voltage or 2 current or 2 voltage)
|
|
Data Capacity
|
32,000
|
|
Dimensions
|
3.1 x 2.1 x 0.9in (7.9 x 5.3 x 2.3cm)
|
|
IP Rating
|
IP20
|
|
Input Connections
|
Screw terminal block
|
|
Input Range
|
0 to 5V (1 to 5V); 0 to 20mA (4 to 20mA)
|
|
Key Features
|
5 Year Battery Life, 0 to 5 V, 0 to 20 mA, or 1 to 5 V
|
|
Network Connectivity
|
EEPROM, Removable Flash Storage Device
|
|
Minimum Software Version Required
|
8.3
|
|
Network Connectivity
|
MP100
|
|
Output Range
|
0 to 5V (1 to 5V); 0 to 20mA (4 to 20mA)
|
|
PC Requirements
|
Minimum of 1 GB RAM; Windows XP (with service pack 3), Vista and Windows 7; 2 available USB ports
|
|
Power Source
|
3V lithium coin cell battery (factory replaceable)
|
|
Power Status Indicator
|
LED Indicator
|
|
Power Source Notes
|
AC Power is optional, but not included.
|
|
Response Time
|
30 Seconds to 63% of Full Scale
|
|
Response Sensor Type
|
Sensor Capability: Any powered voltage or current transmitter with specified recorder input range
|
|
Software Option
|
A015, A016, A025, A026
|
|
Warranty
|
12 Months Limited
|
Product added : May 04 2012 04:19:57 AM

|
 |
|